DESIGN AND CONSTRUCTION OF A COMPUTER MOUSE AID SYSTEM FOR BRACHIAL PLEXUS PATIENTS
Abstract
ABSTRACT
Individuals with Brachial Plexus injuries and other upper-limb mobility impairments often find
it difficult to use traditional computer input devices such as the mouse and keyboard. This
project presents the design and construction of a Computer Mouse Aid system to improve
computer accessibility for people with limited hand functionality. The developed system offers
an alternative method of cursor control and mouse-click operations using a joystick module
and pressure sensors integrated with an Arduino based embedded system.
The system hardware includes an Arduino Nano microcontroller, a joystick module to move
the cursor and two pressure sensors to perform click operations. The sensor inputs are
processed by the Arduino and transmitted to a Python based software application over serial
communication. The software application is developed using Python libraries such as PySerial
and PyAutoGUI to interpret the incoming data and perform corresponding mouse actions
including cursor movement, left-click, right-click and double-click operations.
The system was tested in controlled conditions to evaluate its accuracy, reliability and
sensitivity. The experimental results demonstrated that the device archieved smooth cursor
movement, sensitive click detection, and stable system performance. Calibration of the
pressure and voltage threshold improved click operation accuracy further while decreasing
false triggering. I noticed a few minor software initialization delays on systems that did not
have the required FTDI drivers. However, once the correct drivers were installed, the overall
performance of the system was satisfactory.
The developed system demonstrates that low-cost embedded hardware and sensor technologies
can be effectively utilized to create practical assistive computer interaction devices for
individuals with physical disabilities. The project therefore contributes to the advancement of
affordable assistive technologies aimed at improving accessibility, independence, and ease of
computer use for Brachial Plexus patients and related users.